Vista West

BMAC served as the consultant engineer for full balcony membrane renewal. Initial investigation revealed the need for replacement of the vinyl membrane. BMAC then was hired to provide design/specification documents, building permit, tender process, and field review/contract administration. The system included plywood, vinyl membrane, and railings. Building is a 4-storey wood-frame resting on concrete foundation.

Mechanical Room Upgrade

BMAC conducted a comprehensive assessment of an existing mechanical room with the objective of reducing energy consumption and resolving persistent water leakage issues—without compromising occupant thermal comfort. BMAC developed and presented a detailed report to the council, outlining four cost-effective and sustainable retrofit options.The council elected to proceed with the recommended removal of the existing […]

Centre for Digital Media

Centre for Digital Media is a 10,000 sq.ft. tenant improvement project located within the existing CDM college.Our team was engaged to provide mechanical and plumbing engineering services at the Centre for Digital Media. The scope involved the redesign and modification of existing HVAC and plumbing systems to accommodate the evolving needs of a dynamic educational […]

Hyundai Head Office

Our firm provided comprehensive mechanical and electrical engineering services for the tenant improvement of a new Hyundai showroom. The mechanical scope included HVAC system design to support occupant comfort across showroom, office, and service areas, along with plumbing provisions for staff and customer amenities. Electrical services encompassed power distribution, interior and feature lighting, EV charging […]

Green Gables Beach Resort

Green Gables Beach Resort is a 4-storey resort development featuring 41 premium suites, located in a scenic beachfront setting.Our firm was engaged to provide comprehensive mechanical engineering services, including plumbing, HVAC, and sanitary systems design. Through detailed coordination with the architectural and other disciplines, our mechanical systems were seamlessly integrated into the building design, delivering […]

Downtown Radiology

Downtown Radiology is a 6-storey medical facility designed and constructed to meet Passive House standards, with a focus on energy efficiency, thermal comfort, and sustainable performance. Our firm provided mechanical and plumbing engineering services for this high-performance healthcare project.

Multiplex Building

This Multiplex Building project comprises a main building and an infill building, designed to provide efficient and sustainable urban living. Our firm provided comprehensive engineering services, including mechanical and plumbing system design, building envelope consulting, and energy modelling. Our integrated approach ensured code compliance, energy efficiency, and occupant comfort while supporting the project’s architectural vision. […]

Single Family

Our firm provided comprehensive mechanical engineering services for a high-end single-family residence designed to deliver exceptional comfort and energy efficiency. The project featured a modern architectural layout with premium finishes and expansive living spaces. Our scope included the design and coordination of HVAC systems, mechanical ventilation, and domestic hot water systems tailored to meet the […]

Chemical Lab

BMAC provided mechanical, plumbing, and fire protection engineering services for a specialized chemical laboratory. The HVAC system utilized a high-efficiency VRF system for heating and cooling, supported by ERVs to maintain fresh air supply and indoor air quality.The plumbing design included a chemical neutralization tank to treat lab effluents prior to municipal discharge, ensuring regulatory […]

The Peninsula

BMAC served as the plumbing engineer for the domestic re-piping of an existing 36-storey high-rise located in downtown Vancouver. Our team provided comprehensive engineering design, coordination, and construction support throughout the full replacement of the building’s domestic water distribution system. The design included replacing the existing copper piping with Uponor PEX piping, which offered significant […]